Fireproof compound “Gefest OSD-1” is used for the protection of wooden constructions and objects and materials on wooden basis from the fire, including trimming and sheeting materials, decorations, doors, dividing walls, roof constructions, etc…
Compound “Gefest OSD-1” can be used as trimming material, laying on the other building constructions (brick, concrete, plaster, plywood, HDF or MDF), on the evacuation exits for minimizing their fire danger. For making the cover more weather-proof, it’s allowed to lay on (up to 60 micron) finishing protected lake “GEFEST FFL-1” TOR 2316-005-50021527-2011 or other ones with an agreement of the compound manufacturer. The compound “GEFEST” refers to goods for manufacturing, technical and household purposes and delivers as one-component white mass. According to the customer’s desire the compound can be tinted in plant conditions without loss of fire-proof properties in limited quantity of tones (from light to intensive tones of gray, red-brick and others). Fire-proof cover “Gefest OSD-1” is corresponded with demands of “Technical regulations of fire safety demands” (FL #123 from 22.07.2008) and demands of RNS 53292-2009 “Fire-proof standards of substance for wood and materials on its basis. General demands. Methods of examinations”.
Compound consumption
When protecting wooden constructions the consumption of fire-proof compound “GefestOSD-1” is chosen with due account due necessary fire-protecting efficiency group according to RNS 53292-2009.
Fire-proof efficiency group of cover |
Loss of mass in fire examinations |
Consumption of fireproof compound “Gefest OSD-1" |
---|---|---|
I |
9 |
0,31 |
II |
25 |
0,19 |
Laying
Fireproof compound laying works should be done under the atmosphere condition in accordance with RNS 17.2.3.02б under the temperature not less than 5̊C, relative atmosphere humidity should not be less than 80% according to TR of laying.
Fireproof compound is laid on the prepared wooden surfaces layer-by-layer, with the usage of manual instrument (brushes, rollers) or by methods of air or air-free spraying.
Transportation and storage
Transportation and storage of the compound “Gefest FCW-1” – according to RNS 9980.5. Transportation can be accomplished by any type of covered vehicle in accordance with the transportation regulations, operating for the given type of vehicle. During the winter, transportation is practiced in draft-proof vehicles.
Compound storage is practiced in hermetically closed boxing in heated space on the distance not less than 2 meters from heated instruments in conditions excluding the influence of water and aggressive substances. Prevent direct sunlight. Storage temperature: from +5̊C to +40̊C. Expiry date of the closed plant box is 12 months from the moment of manufacturing.
Freezing of compound “Gefest OSD-1” is forbidden
Warranty life of the cover “Gefest OSD-1” in space without lowing of fire-proof efficiency – is not less than 10 years.
Packaging
In general, the compound is packaged in buckets (20kg) and canisters (50 kg). Depending on the customer’s desire other types of packaging are available.